Research Article
Application Value of Serum TK1 and PCDGF, CYFRA21-1, NSE, and CEA plus Enhanced CT Scan in the Diagnosis of Nonsmall Cell Lung Cancer and Chemotherapy Monitoring
Table 3
Comparison of detection outcomes.
95% confidence interval
Variables
Area
Standard error
a
Progressive sig.
B
Lower limit
Upper limit
TK1
0.667
0.071
0.027
0.528
0.806
PCDGF
0.633
0.072
0.076
0.491
0.775
CYFRA21-1
0.700
0.069
0.008
0.565
0.835
NSE
0.700
0.069
0.008
0.565
0.835
CEA
0.733
0.066
0.002
0.603
0.864
CT
0.817
0.058
0.000
0.703
0.931
TK1+PCDGF+CYFRA21-1+NSE+CEA
0.833
0.056
0.000
0.724
0.943
Joint detection
0.900
0.045
0.000
0.812
0.988