Research Article
A Rabbit Model Study to Determine the Efficacy of a Prototype Corneal Endothelium Protector during Cataract Surgery
Table 2
Postoperative percentage endothelial cell loss and mean number of endothelial cells by histological analysis.
| | Mean preoperative ECC (cells/mm2) | Percentage endothelial cell loss (%) | Mean ECC by histological analysis (cells/field diameter) | POD1 | POD5 | POD7 | POD14 |
| Group A () | 2510 ± 297 (SEM 112) | 4.9 ± 9.2% (SEM 6.50) | 10.4 ± 12.4% (SEM 5.53) | 10.5 ± 9.7% (SEM 4.87) | 9.8 ± 0.52% (SEM 0.37) | 31.6 ± 1.5 (SEM 0.6) | Group B () | 2980 ± 100 (SEM 33) | 12.5% ± 14.9% (SEM 6.06) | 12.2% ± 10.0% (SEM 3.55) | 17.2% ± 18.0% (SEM 7.35) | 4.7% ± 11.4% (SEM 6.60) | 32.5 ± 1.5 (SEM 0.5) | value | 0.001 | 0.53 | 0.77 | 0.52 | 0.59 | 0.24 |
|
|