Clinical Study

Pupil Size Associated with the Largest Iris Volume in Normal Chinese Eyes

Table 3

Parameters at baseline and at one hour after induction of miosis ().

VariablesMEFE
BaselineAfter one hourBaselineAfter one hour

IOP (mmHg)15.21 ± 3.4313.81 ± 3.310.00315.00 ± 4.3513.71 ± 3.600.018
PS (mm)5.02 ± 0.923.08 ± 1.190.0015.03 ± 0.874.37 ± 1.150.001
ACV (mm3)152.69 ± 39.41140.48 ± 35.240.001149.63 ± 38.66144.66 ± 37.320.023
IV (mm3)26.21 ± 7.6330.02 ± 4.400.00226.79 ± 7.3828.05 ± 1.210.112
ACD (mm)2.86 ± 0.352.79 ± 0.340.0012.84 ± 0.362.81 ± 0.390.134

ME: miosis-induced eye; FE: fellow eye; IV: iris volume.