Research Article

The Topographical Effect of Optical Zone Diameter in Orthokeratology Contact Lenses in High Myopes

Table 5

Corneal and total spherical aberration measured with Visionix VX110 at 5 mm pupil diameter.

Corneal Z12 (µm)Total Z12 (µm)
Visit5 mm OZ lens6 mm OZ lensp value5 mm OZ lens6 mm OZ lens value

PRE0.144 ± 0.0300.132 ± 0.0290.8540.041 ± 0.0540.011 ± 0.0290.456
1 day0.403 ± 0.0830.331 ± 0.0890.526
7 days0.644 ± 0.1010.477 ± 0.1530.027
15 days0.603 ± 0.1160.476 ± 0.1240.0390.574 ± 0.4960.451 ± 0.1990.043

Values are expressed as mean ± SD. SD: standard deviation; OZ: optical zone; Z12: 4th spherical aberration.  < 0.05 comparison between lenses (Student's t-test for paired samples).