Research Article
Posterior-Chamber Phakic Intraocular Lens Implantation in Patients over 40 Years of Age
Table 1
Preoperative patient demographics and ICL characteristics.
| | Mean ± SD | Range [min, max] |
| Age (years) | 43.52 ± 4.49 | [40, 56] | Refraction sphere (D) | −8.18 ± 2.66 | [−13.5, −2] | Refraction cylinder (D) | −1.55 ± 1.18 | [−4.0, 0] | Spherical equivalent (D) | −8.46 ± 3.31 | [−14.88, −1.88] | Corneal thickness (μm) | 535.18 ± 36.66 | [452, 580] | CDVA (decimal) | 0.88 ± 0.18 | [0.40, 1.00] | ACD (mm) | 3.07 ± 0.26 | [2.67, 3.59] | WTW (mm) | 12.16 ± 0.41 | [11.30, 12.70] | ATA (mm) | 12.07 ± 0.39 | [11.50, 12.79] | ECD (cells/mm2) | 2568 ± 332 | [2004, 3297] | IOP (mmHg) | 16.23 ± 3.61 | [10, 24] | ICL sphere (D) | −9.52 ± 2.65 | [−15.0, −1.0] | ICL cylinder (D) | 2.65 ± 1.23 | [1, 4.5] | ICL size (mm) | 12.96 ± 0.35 | [12.10, 13.20] |
|
|
ICL: implantable Collamer lens; SD: standard deviation; D: diopters; CDVA: corrected-distance visual acuity; ACD: anterior chamber depth; WTW: white-to-white; ATA: angle-to-angle; ECD: endothelial cell density; IOP: intraocular pressure.
|