Research Article

Preliminary Clinical Study of a LenSx Femtosecond Laser-Assisted Limbal Relaxing Incision for the Correction of High Myopia with Low to Moderate Astigmatism in Posterior Implantable Collamer Lens Implantation

Table 2

The UDVA and CDVA before and after surgery in each group.

ParameterPre-CDVA (LogMAR)Post-CDVA (LogMAR)Post-UDVA (LogMAR)

1 monthLenSx + ICL group0.052 ± 0.051−0.043 ± 0.050−0.038 ± 0.059
TICL group0.030 ± 0.047−0.083 ± 0.058−0.083 ± 0.058
ICL group0.025 ± 0.044−0.025 ± 0.055−0.025 ± 0.055
value

3 monthsLenSx + ICL group0.052 ± 0.051−0.076 ± 0.044−0.029 ± 0.046
TICL group0.030 ± 0.047−0.091 ± 0.060−0.083 ± 0.072
ICL group0.025 ± 0.044−0.040 ± 0.050−0.015 ± 0.049
P value

6 monthsLenSx + ICL0.052 ± 0.051−0.071 ± 0.046−0.033 ± 0.048
group
TICL group0.030 ± 0.047−0.078 ± 0.052−0.083 ± 0.065
ICL group0.025 ± 0.044−0.055 ± 0.051−0.020 ± 0.052
value

logMAR = logarithm of the minimum angle of resolution, CDVA = corrected distance visual acuity, UDVA = uncorrected distance visual acuity, Pre = preoperative, and Post = postoperative. Means ± SD, the values in the table shows the comparison among the three groups.