Research Article

Outcomes and Complications of Sutured Scleral-Fixated Foldable Intraocular Lens Implantation: A Retrospective Study of 5-Year Follow-Up

Figure 1

Sutured scleral-fixated implantation with a one-piece foldable IOL. (a) The suture was tied to the maximum radian of the IOL haptic with at least 5 knots. (b) After withdrawing the plunger, the haptic drew back into the cartridge.