Changes in Intraocular Pressure after Transepithelial Photorefractive Keratectomy and Femtosecond Laser In Situ Keratomileusis

Table 4

Potential factors affecting the changes in bIOP after FS-LASIK and TPRK were analyzed with marginal linear regression models using the GEE.

Univariate valueMultivariate value
BSE95% CIBSE95% CI

Group
LASIKRef.Ref.
PRK1.85(0.37)(1.13, 2.57)<0.0011.64(0.47)(0.72, 2.57)0.001
Gender
MaleRef.
Female−0.42(0.47)(−1.35, 0.50)0.370
Age (year)−0.02(0.02)(−0.07, 0.03)0.371
SE (D)0.07(0.09)(−0.10, 0.24)0.409
Average K (D)0.01(0.17)(−0.33, 0.35)0.950
Depth of ablation (μm)−0.01(0.01)(−0.02, 0.00)<0.1090.002(0.01)(−0.01, 0.01)0.702
bIOP preop (mmHg)−0.63(0.10)(−0.83, −0.43)<0.001
CCT (μm)0.00(0.01)(−0.01, 0.02)0.727
A1L (mm)−0.27(0.48)(−1.21, 0.66)0.567
A1V (m/s)18.54(7.99)(2.87, 34.21)0.020−4.20(10.60)(−24.97, 16.57)0.692
A2L (mm)−0.63(0.34)(−1.30, 0.03)0.061
A2V (m/s)−11.02(7.87)(−26.44, 4.40)0.161
A1T (ms)−3.59(0.52)(−4.61, −2.57)<0.001
A2T (ms)1.63(0.52)(0.61, 2.65)<0.002
Radius (mm)−0.02(0.14)(−0.30, 0.26)0.876
PD (mm)2.96(0.69)(1.61, 4.32)<0.0012.35(0.81)(0.77, 3.94)0.004
DA (mm)7.61(1.60)(4.47, 10.76)<0.001
Young’s modulus (MPa)0.13(0.18)(−0.23, 0.49)0.469
CBI0.69(0.35)(0.00, 1.38)0.0500.09(0.35)(−0.60, 0.78)0.798
DA ratio0.42(0.31)(−0.18, 1.02)0.167
Integr. radius (mm−1)0.32(0.15)(0.03, 0.61)0.0290.001(0.22)(−0.43, 0.43)0.997
ARTh0.00(0.00)(−0.00, 0.00)0.699
SP-A1−0.02(0.02)(−0.05, 0.01)0.169

∆bIOP = −13.39 + 1.64 (PRK) − 4.20 (A1V) + 2.35 (peak distance) + 0.09 (CBI) + 0.001 (Integr. radius) + 0.002 (ablation depth). GEE, generalized estimating equation. and . FS-LASIK, femtosecond laser in situ keratomileusis; TPRK, transepithelial photorefractive keratectomy; SE, spherical equivalent; K, keratometric readings in diopter; IOP, intraocular pressure; bIOP, biomechanically corrected IOP; A1L, first applanation length; A1V, applanation-1 velocity; A2L, second applanation length; A2V, applanation-2 velocity; PD, peak distance; DA, deformation amplitude; CCT, central corneal thickness; A1T, applanation-1 time; A2T, applanation-2 time; CBI, Corvis Biomechanical Index; DA ratio, DA ratio at 2.0 mm; Integr. radius, the integrated area under the radius of the inversed curvature during the concave phase; ARTh, Ambrósio’s relational thickness in the horizontal profile; SP-A1, stiffness parameter at applanation 1.