Characteristics of Anterior Segment in Congenital Ectopia Lentis: An SS-OCT Study

Table 2

Comparison of angle parameters in different direction in CEL patients and healthy controls.

Angle parametersCELHealthy controls
Contralateral side to dislocated lens sideDislocated lens side
(Mean ± SD, )

(Mean ± SD, )
90°
(Mean ± SD, )
180°
(Mean ± SD, )
270°
(Mean ± SD, )

AOD250, mm0.27 ± 0.130.46 ± 0.16 <0.0010.51 ± 0.13
<0.001
0.45 ± 0.15
<0.001
0.57 ± 0.18
<0.001
0.46 ± 0.14
<0.001
AOD500, mm0.37 ± 0.150.63 ± 0.19 <0.0010.74 ± 0.16
<0.001
0.67 ± 0.19
<0.001
0.82 ± 0.23
<0.001
0.66 ± 0.16
<0.001
AOD750, mm0.51 ± 0.190.84 ± 0.22
<0.001
0.98 ± 0.18
<0.001
0.89 ± 0.21
<0.001
1.10 ± 0.25
<0.001
0.89 ± 0.22
<0.001
ARA250, mm20.10 ± 0.060.17 ± 0.09
<0.001
0.18 ± 0.05
<0.001
0.15 ± 0.07
<0.001
0.19 ± 0.06
<0.001
0.16 ± 0.06
<0.001
ARA500, mm20.17 ± 0.080.29 ± 0.13
<0.001
0.33 ± 0.09
<0.001
0.29 ± 0.10
<0.001
0.35 ± 0.11
<0.001
0.29 ± 0.10
<0.001
ARA750, mm20.28 ± 0.120.48 ± 0.18
<0.001
0.55 ± 0.13
<0.001
0.48 ± 0.14
<0.001
0.59 ± 0.17
<0.001
0.48 ± 0.14
<0.001
TISA250, mm20.057 ± 0.030.10 ± 0.04
<0.001
0.11 ± 0.03
<0.001
0.09 ± 0.04
<0.001
0.12 ± 0.04
<0.001
0.10 ± 0.03
<0.001
TISA500, mm20.14 ± 0.060.24 ± 0.09
<0.001
0.27 ± 0.07
<0.001
0.24 ± 0.08
<0.001
0.30 ± 0.09
<0.001
0.24 ± 0.07
<0.001
TISA750, mm20.25 ± 0.100.43 ± 0.14
<0.001
0.50 ± 0.11
<0.001
0.44 ± 0.12
<0.001
0.54 ± 0.15
<0.001
0.44 ± 0.11
<0.001
TIA250,°33.51 ± 12.6144.41 ± 8.40
<0.001
49.70 ± 11.36
<0.001
44.28 ± 12.11
<0.001
52.42 ± 11.59
<0.001
45.65 ± 11.61
<0.001
TIA500°29.70 ± 8.1341.45 ± 7.09
<0.001
47.29 ± 9.13
<0.001
43.37 ± 9.68
<0.001
49.92 ± 9.16
<0.001
43.41 ± 9.64
<0.001
TIA750°28.99 ± 7.9940.84 ± 6.99
<0.001
46.37 ± 7.19
<0.001
43.14 ± 7.95
<0.001
49.65 ± 7.57
<0.001
42.93 ± 8.49
<0.001

AOD, angle open distance; ARA, angle recess area; TISA, trabecular-iris space area; TIA, trabecular-iris angle; t-test for comparison of means with angle parameters of contralateral side to dislocated lens side in CEL patients.