Research Article

Multiobjective Design of Wearable Sensor Systems for Electrocardiogram Monitoring

Table 4

Model fitness evaluated by the coefficient of determination. Notation [ ] stands for the fixed output variable.

Objective function Predictors Coefficient of determination ()
Linear regressor FNN

Functionality 0.18767 0.56778
0.48498 0.77891
0.48237 0.80344

Wearability 0.19002 0.59549
0.73312 0.88013
0.73611 0.8747