Review Article

Accelerometer Sensor Specifications to Predict Hydrocarbon Using Passive Seismic Technique

Table 11

Survey based on type of devices used for seismic data acquisition [31].

ParametersMolecular Electronic Transducers (MET) SensorGeophonesMEMS
accelerometers
Implication

Frequency range 1–500 Hz10–190 HzDC – 1000 HzBetter imaging of deep, shallow, and/or narrow layers of deposits

Scale factor stability<50 ng/500 ng/Higher data quality

Sensor noiseLowLowModerateHigher data quality

SensitivityHighLowLowLonger life in the field

Shock toleranceVery highModerateHighUsable in a wider range of surveys

Electromagnetic interferenceNoYesNoNo power line pickup: better data with less processing required

PowerLowLowHighLess expensive to operate, longer battery life

CostLow-medLowHighLower equipment cost