Research Article
Precession Azimuth Sensing with Low-Noise Molecular Electronics Angular Sensors
Table 1
Technical parameters of molecular electronic angular motion sensor.
| Parameter | Molecular electronic angular motion sensor | Molecular electronic angular accelerometer |
| Transducer diameter | 50 mm | 9 mm | Output signal type | Analog, nondifferential, proportional to angular velocity | Analog, nondifferential, proportional to angular acceleration | Photo (Figure 4 MET 50 mm; Figure 5 MET 9 mm) |
See Figure 4 |
See Figure 5 | Service band | 30 sec – 20 Hz | 0–50 Hz | Transduction coefficient | 50 B/(rad/sec) | 0.5 B/(rad/sec2) | Maximum bandpass flatness in service band | ±0.4 dB | ±0.5 dB | Maximum output signal | ±5 V | ±10 V | Maximal measured signal with harmonic distortions of <2% | 0.01 rad/sec | 5.2 rad/sec2 | Noise spectral density in the frequency range of 0.01–3 Hz [23, 24] | 7.5 · 10−7 rad/(sec2·√Hz) | 10−4 rad/(sec2·√Hz) | Operating temperature range |
−12–+55°C |