Research Article

Precession Azimuth Sensing with Low-Noise Molecular Electronics Angular Sensors

Table 1

Technical parameters of molecular electronic angular motion sensor.

ParameterMolecular electronic angular motion sensor Molecular electronic angular accelerometer

Transducer diameter50 mm9 mm
Output signal typeAnalog, nondifferential, proportional to angular velocity Analog, nondifferential, proportional to angular acceleration
Photo (Figure 4 MET 50 mm; Figure 5 MET 9 mm) See Figure 4 See Figure 5
Service band30 sec – 20 Hz0–50 Hz
Transduction coefficient50 B/(rad/sec)0.5 B/(rad/sec2)
Maximum bandpass flatness in service band ±0.4 dB±0.5 dB
Maximum output signal±5 V±10 V
Maximal measured signal with harmonic distortions of <2% 0.01 rad/sec5.2 rad/sec2
Noise spectral density in the frequency range of 0.01–3 Hz [23, 24]7.5 · 10−7 rad/(sec2·√Hz)10−4 rad/(sec2·√Hz)
Operating temperature range −12–+55°C −12–+55°C
Maximum error of temperature compensation in service band<10%<3%
Possible installation angleAnyAny
Mass50 g8 g
Power 12 V12 V
Input5 mA1.4 mA