Research Article

Identifying and Correcting Step Losses in Single-Ended Fiber-Optic Distributed Temperature Sensing Data

Table 2

(a) Calibration, validation, and near-splice metrics from the uncorrected and corrected calibration schemes as applied to the synthetic data set. (b) Calibration, validation, and near-splice metrics from the corrected and uncorrected calibration schemes as applied to the laboratory test data.
(a)

Uncorrected metrics
of 1440 traces
°C
Corrected metrics
of 1440 traces
°C

CalibrationRMSE0.023 ± 0.0010.02 ± 0.001
Bias<10−5<10−5

ValidationRMSE0.09 ± 0.0050.02 ± 0.002
Bias−0.09 ± 0.0050 ± 0.005

475–499 mRMSE0.89 ± 0.0050.02 ± 0.005
Bias0.89 ± 0.0050.00 ± 0.01

501–525 mRMSE0.89 ± 0.0050.02 ± 0.005
Bias−0.89 ± 0.0050.00 ± 0.01

(b)

Uncorrected metrics
of 208 traces
°C
Corrected metrics
of 208 traces
°C

CalibrationRMSE0.10 ± 0.020.09 ± 0.02
Bias<10−4<10−4

ValidationRMSE0.20 ± 0.030.15 ± 0.05
Bias0.14 ± 0.020.03 ± 0.03

104–118 mRMSE0.38 ± 0.020.14 ± 0.04
Bias−0.39 ± 0.02−0.13 ± 0.04

129–144 mRMSE0.14 ± 0.020.15 ± 0.05
Bias0.12 ± 0.02−0.13 ± 0.06