Research Article

The Differential Method for Force Measurement Based on Electrostatic Force

Table 2

Uncertainty of capacitance gradient.

Uncertainty sourcesContribution to total uncertainty (%)

Electrode alignment0.05
The repeatability0.03
Capacitance bridgeNegligible
DisplacementNegligible
Combined0.06