Research Article

Microfluidic Biosensor Based on Microwave Substrate-Integrated Waveguide Cavity Resonator

Table 1

Design parameters of the SIW cavity resonator proposed as a biosensor.

ParameterDimension (mm)ParameterDimension (mm)ParameterDimension (mm)ParameterDimension (mm)

WSUB28LM8LQT3.5d11.8
LSUB33WM2.25WQT0.3d24
W14a1.5h11.2D0.9
L13b0.5h21.5P1.5