Research Article
Measuring Occupants’ Behaviour for Buildings’ Dynamic Cosimulation
Table 2
Statistical analysis of the monitored variables during the heating season, the nonheating season, and the total period (only occupied periods).
| Season | | Indoor temp. (°C) | Outdoor temp. (°C) | Indoor humidity (%) | CO2 (ppm) | Work-plane illuminance (lx) |
| Total | Max | 34.1 | 34.6 | 77 | 1660 | 2000 | Min | 15.4 | −2.7 | 21 | 363 | 0 | Mean | 23.9 | 17.3 | 44 | 650 | 357 | St. dev. | 2.6 | 7.5 | 10.5 | 186 | 196 |
| Heating season | Max | 28.6 | 23.8 | 65 | 1543 | 944 | Min | 15.6 | −2.7 | 21 | 375 | 0 | Mean | 22.7 | 11.7 | 37 | 713 | 336 | St. dev. | 1.1 | 5.0 | 7.6 | 150 | 142 |
| Nonheating season | Max | 34.1 | 34.6 | 77 | 1660 | 2000 | Min | 15.4 | 8.4 | 24 | 363 | 0 | Mean | 24.9 | 22.5 | 50 | 593 | 376 | St. dev. | 3.1 | 5.2 | 8.6 | 198 | 235 |
|
|