Research Article
A Study of the Multisensor Estimation Method Based on Fusion Technology for Subsurface Defect Depth
Table 1
The evaluation results of the surface material defect depth using three methods.
| Number | The real defect depth | Echo arrival time feature (ms) of ultrasonic testing | Amplitude feature (V) of eddy current testing | The depth of UT | The depth of ECT | The depth of multisensor testing |
| 1 | 4.5 | 21.48 | 0.578 | 4.49 | 3.05 | 4.49 | 2 | 4 | 21.09 | 0.574 | 4.36 | 3.13 | 4.36 | 3 | 3.5 | 20.56 | 0.583 | 4.13 | 2.72 | 3.75 | 4 | 3 | 19.88 | 0.587 | 3.69 | 2.49 | 3.17 | 5 | 2.5 | 19.21 | 0.593 | 3.27 | 2.22 | 2.64 | 6 | 2 | 18.43 | 0.601 | 2.99 | 1.81 | 1.86 | 7 | 1.5 | 18.27 | 0.607 | 2.68 | 1.44 | 1.44 | 8 | 1 | 18.08 | 0.612 | 2.53 | 1.04 | 1.04 |
|
|