Research Article

A Study of the Multisensor Estimation Method Based on Fusion Technology for Subsurface Defect Depth

Table 1

The evaluation results of the surface material defect depth using three methods.

NumberThe real defect depthEcho arrival time feature (ms) of ultrasonic testingAmplitude feature (V) of eddy current testingThe depth of UTThe depth of ECTThe depth of multisensor testing

14.521.480.5784.493.054.49
2421.090.5744.363.134.36
33.520.560.5834.132.723.75
4319.880.5873.692.493.17
52.519.210.5933.272.222.64
6218.430.6012.991.811.86
71.518.270.6072.681.441.44
8118.080.6122.531.041.04