Research Article
Research and Application of Heavy-Equipment Parachute Rope Tension Sensor
Table 1
Temperature error of the sensor without compensation.
| Tension (kN) | V out (V) | Errtemp (%FS) | −20°C | −10°C | 0°C | +10°C | +20°C | +30°C | +40°C |
| 0 | 0.012 | 0.015 | 0.017 | 0.017 | 0.019 | 0.025 | 0.044 | 0.50% | 20 | 0.969 | 0.972 | 0.991 | 1.003 | 1.011 | 1.020 | 1.034 | 0.84% | 40 | 1.930 | 1.942 | 1.961 | 1.985 | 2.006 | 2.198 | 2.041 | 1.52% | 60 | 2.892 | 2.920 | 2.953 | 2.962 | 2.975 | 3.021 | 3.033 | 1.66% | 80 | 3.859 | 3.870 | 3.894 | 3.908 | 3.925 | 3.940 | 3.956 | 1.32% | 100 | 4.817 | 4.833 | 4.845 | 4.857 | 4.862 | 4.882 | 4.896 | 0.90% |
|
|