Research Article
Research and Application of Heavy-Equipment Parachute Rope Tension Sensor
Table 4
The results of the test in room temperature (temperature: 20°C, humidity is 62% RH).
| Standard force value (kN) | Uptravel output (V) | Repeatability (%FS) | Theoretical value (V) | Nonlinearity (%FS) | Downtravel output (V) | Precision (%FS) | 1 | 2 | 3 | Average | 1 | 2 | 3 |
| 0 | 0.039 | 0.008 | 0.011 | 0.019 | 0.64 | 0.019 | 0.00 | 0.007 | 0.012 | 0.017 | 0.41 | 20 | 1.037 | 0.991 | 1.005 | 1.011 | 0.95 | 0.988 | 0.47 | 1.056 | 1.020 | 1.037 | 1.40 | 40 | 2.040 | 1.978 | 2.001 | 2.006 | 1.28 | 1.956 | 1.03 | 2.085 | 2.030 | 2.068 | 2.65 | 60 | 3.006 | 2.942 | 2.977 | 2.975 | 1.32 | 2.925 | 1.03 | 3.072 | 3.130 | 3.065 | 2.88 | 80 | 3.942 | 3.893 | 3.939 | 3.925 | 1.01 | 3.893 | 0.66 | 3.975 | 4.006 | 4.036 | 2.94 | 100 | 4.860 | 4.831 | 4.896 | 4.862 | 1.34 | 4.862 | 0.00 | | | | 0.70 |
|
|