Research Article

Improving Accuracy in the Readout of Resistive Sensor Arrays

Table 6

Results obtained for methods based on the VFM by changing the size of the array and maintaining  kΩ and  Ω. (a) Classical approach. (b) VFM circuit proposed by Wu et al. (c) Results for the proposed method in the first step. (d) Results for the proposed method in the second step.
(a) VFM classical approach

Rns = 2 kΩ
Size
Error (%), (Ω)
10050020005000750010000

4 × 411.603.532.011.711.641.60
6 × 612.664.543.012.692.612.56
8 × 813.725.564.023.673.573.50
10 × 1014.796.595.024.644.524.43
12 × 1215.867.626.025.615.455.33
14 × 1416.948.657.026.566.376.21
16 × 1618.029.688.027.517.277.07

(b) VFM-Wu

Rns = 2 kΩ
Size
Error (%), (Ω)
10050020005000750010000

4 × 410.772.761.250.950.880.84
6 × 611.273.261.751.431.351.30
8 × 811.773.752.231.891.791.73
10 × 1012.274.252.712.352.222.13
12 × 1212.774.743.192.792.632.52
14 × 1413.275.243.663.223.032.88
16 × 1613.775.734.133.633.413.21

(c) VFM proposed method, 1st step

Rns = 2 kΩ
Size
Error (%), (Ω)
10050020005000750010000

4 × 40.610.080.050.040.050.05
6 × 60.730.140.090.090.090.09
8 × 80.870.220.150.150.150.15
10 × 101.020.310.240.220.220.22
12 × 121.180.420.330.310.300.30
14 × 141.150.550.440.410.390.38
16 × 160.070.680.560.520.500.48

(d) VFM proposed method, 2nd step

Rns = 2 kΩ
Size
Error (%), (Ω)
10050020005000750010000

4 × 40.060.010.010.020.020.02
6 × 60.070.020.010.020.030.03
8 × 80.090.020.020.030.030.04
10 × 100.110.030.030.030.040.04
12 × 120.130.040.040.040.050.05
14 × 140.080.060.050.050.060.06
16 × 161.560.070.060.060.070.07