Table 1

Intrinsic frequencies of F-P sensors with different physical dimensions.

SensorDiameter
(mm)
Thickness
(μm)
Simulation intrinsic frequency (kHz)

F-P #11.850169.7
F-P #21.840135.8
F-P #31.120181.9
F-P #41.540195.3