Research Article

Quantitative Nondestructive Testing of Broken Wires for Wire Rope Based on Magnetic and Infrared Information

Table 6

Recognition accuracy for different values of in KNN algorithm.

Accuracy

Magnetic data86.3%83.0%77.7%78.2%77.5%78.0%76.8%76.3%
Infrared data88.4%90.3%88.6%89.0%89.6%88.8%88.0%87.2%
Fused data97.2%98.9%98.0%97.9%97.7%97.4%96.8%96.0%