Research Article
Vibration Diagnosis and Treatment for a Scrubber System Connected to a Reciprocating Compressor
Table 1
Measurement sensors and the main specifications.
| Sensor | Measuring parameter | Type | Technical specifications |
| Accelerometer | Vibration | PCB 608A11 | Range: 0.5 Hz to 10 kHz Sensitivity(±15%): 100 mV/g Measurement range: ±50 g Broadband resolution: 350 μg | Pressure transmitter | Pressure | Wotian PCM 301 | Range: 0~30 MPa Accuracy: ±0.5% Response time: ≤1 ms Shock: 100 g | Impact hammer | Modal | PCB 086D20 | Range: ±22,240 N pk Sensitivity (±15%): 0.23 mV/N Resonant frequency: 12 kHz Nonlinearity: 1% |
|
|