Data collected of the PV system in different states under different environmental conditions.

StateIrradiationTemperatureWeather
AmpsVoltsklux°C

NormalMax7.611011041Sunny/summer
5.41029723Cloudy/summer
Min5.510510815Sunny/winter
0.4809-3Cloudy/winter
OpenMax7.611010815Sunny/winter
Min009-3Cloudy/winter
Line-lineMax6.19011041Sunny/summer
1.8729723Cloudy/summer
Min5.57510815Sunny/winter
0.4629-3Cloudy/winter
Variance0.527.2335.568.7Summer
4.829.5447.6115.24Winter