Research Article
Design and Development of a Flexible, Plug-and-Play, Cost-Effective Tool for on-Field Evaluation of Gas Sensors
Table 6
Results for the sensors involved in the outdoor experiment related to the calibration and validation datasets.
| Sensor/model | Calibration | Validation | R2 | MAE | SD | R2 | MAE | SD | SLOPE | INTERCEPT |
| NO2B43F(1)/LR | 0.377 | 2.29 | 3.069 | 0.357 | 2.382 | 2.893 | 0.859 | 0.461 | NO2B43F(1)/MLR | 0.465 | 2.164 | 2.844 | 0.32 | 3.587 | 3.397 | 0.547 | 5.388 | NO2B43F(2)/LR | 0.369 | 2.239 | 3.088 | 0.466 | 2.346 | 2.632 | 1.137 | -2.468 | NO2B43F(2)/MLR | 0.61 | 1.856 | 2.426 | 0.507 | 2.461 | 2.62 | 0.781 | 0.515 | OXB431(1)/LR | 0.47 | 4.736 | 6.491 | 0.455 | 5.201 | 6.681 | 1.05 | -1.809 | OXB431(1)/MLR | 0.643 | 4.147 | 5.33 | 0.373 | 6.591 | 7.278 | 0.81 | 9.28 | OXB431(2)/LR | 0.474 | 4.624 | 6.471 | 0.614 | 7.071 | 5.746 | 1.205 | -13.571 | OXB431(2)/MLR | 0.666 | 3.483 | 5.154 | 0.668 | 8.13 | 5.412 | 0.834 | -1.124 | SP-61(1)/LR | 0.427 | 5.153 | 6.75 | 0.282 | 5.974 | 8.169 | 0.629 | 10.831 | SP-61(1)/MLR | 0.484 | 4.624 | 6.408 | 0.344 | 5.628 | 7.79 | 0.667 | 10.268 | SP-61(2)/LR | 0.434 | 5.067 | 6.677 | 0.3 | 5.724 | 7.967 | 0.664 | 10.357 | SP-61(2)/MLR | 0.492 | 4.557 | 6.355 | 0.361 | 5.546 | 7.637 | 0.688 | 10.228 |
|
|