Research Article

Parameter Recognition of Mode-Converted Wave in Single-Source Ultrasound Using Gabor Transform for Bolt Axial Stress Evaluation

Table 4

Estimated TOF of sample .

Axial stress (MPa)TOF of L (μS)TOF of LC(μS)TOF of S(μS)

037.76352.27165.4171.384190.57727
1037.77052.27965.4271.384140.57728
2037.77852.28965.4351.384110.57734
3037.78552.29865.4491.384090.57732
4037.79352.30865.4601.384070.57734
5037.79952.31665.4711.384060.57734
6037.80852.32765.4801.384020.57740
7037.81552.33665.4911.384000.57741
8037.82252.34465.5021.383960.57742
9037.82952.35365.5131.383940.57743
10037.83652.36265.5241.383920.57744
11037.84252.37065.5341.383910.57744
12037.84952.37965.5451.383890.57745
13037.85652.38765.5561.383850.57746
14037.86652.39965.5661.383800.57752
15037.87452.40865.5771.383750.57755
16037.88152.41665.5871.383700.57757
17037.88752.42465.5981.383690.57756
18037.89352.43165.6031.383660.57761
19037.90152.43965.6211.383580.57757