Research Article

Parameter Recognition of Mode-Converted Wave in Single-Source Ultrasound Using Gabor Transform for Bolt Axial Stress Evaluation

Table 5

Estimated TOF of sample .

Axial stress (MPa)TOF of L (μS)TOF of LC(μS)TOF of S(μS)

076.194105.170133.3461.380290.57140
1076.207105.186133.3651.380270.57142
2076.222105.204133.3861.380230.57144
3076.236105.221133.4151.380200.57142
4076.250105.238133.4281.380170.57147
5076.265105.256133.4501.380140.57149
6076.279105.274133.4751.380120.57149
7076.292105.289133.4891.380080.57152
8076.305105.305133.5101.380050.57153
9076.315105.317133.5301.380030.57152
10076.328105.333133.5451.380000.57155
11076.343105.351133.5731.379970.57155
12076.358105.368133.5911.379920.57158
13076.373105.386133.6211.379890.57156
14076.387105.403133.6391.379860.57159
15076.402105.421133.6581.379820.57162
16076.416105.438133.6851.379790.57161
17076.430105.456133.7011.379770.57165
18076.443105.471133.7211.379730.57166
19076.452105.481133.7381.379700.57166