Research Article
FBG-Based Sensing for Structural Health Monitoring of Road Infrastructure
Table 2
Measured strain (
μm/m) by FBG sensor that is embedded 25 mm under FWD when 6 drops by
load are performed (with temperature compensation enabled).
| No. of FWD drop | Center location of the FWD plate with respect to the FBG sensor (mm) | 0 | 300 | 600 | 900 |
| 1 | 162.5 | 91.5 | 24.6 | 12.5 | 2 | 145.9 | 77.6 | 27.0 | 13.1 | 3 | 142.7 | 80.5 | 24.2 | 12.2 | 4 | 149.5 | 73.4 | 28.3 | 12.1 | 5 | 161.6 | 85.8 | 25.7 | 13.2 | 6 | 148.5 | 71.2 | 25.1 | 13.2 | Average value of measured strain (μm/m) | | | | |
|
|