Research Article

[Retracted] Environmental Impact Assessment of Production Plant during Construction Period

Table 6

Intensity and distance limits of different noise sources.

Name of noise sourcesIntensity of noise source (dB)Minimum interference radius of different limits (m)
70 dB (day)55 dB (night)

Electric saw10345251
Bending machine9050281
Carpenter’s plane8721119
Concrete mixer8721119
Electric welding machine8632177
Concrete pump truck8528158
Excavator8118100
Steel bar shearing machine771688