The key parameters of the above three kinds of substrates. The values of are larger than the one order of magnitude from each other.

TypesParameter(a)(b)(c)

SubstrateMaterialsARLON AD-450FR-4Denim fabric
Dielectric constant ()4.505.202.16
Loss tangent ()0.0020.0150.114
Thickness (mm)1.581.500.56
ConductorMaterialsCopperCopperCopper
Thickness (mm)0.0350.0180.018