Test parameters of adaptive control system.
| Subsystem | Parameter | Value |
| Cutter head system | Relief valve opening pressure MPa | 17 | Displacement of cutter head motor mL/r | 84.6 | Displacement of cutter head pump mL/r | 60 | Rotation speed of cutter head pump r/min | 2400 |
| Walking system | Flushing valve overflow valve opening pressure MPa | 1.7 | Opening pressure of charge pump relief valve MPa | 3.0 | Opening pressure of main relief valve MPa | 25 | Displacement of travel charge pump mL/r | 15 | Displacement of walking motor mL/r | 1690 | Displacement of walking main pump mL/r | 70 | Engine speed r/min | 2400 |
|
|