Research Article

Simulation Analysis of Eddy Current Testing Parameters for Surface and Subsurface Defect Detection of Aviation Aluminum Alloy Plate

Table 4

Influence of excitation frequency on defect detection.

Frequency range (kHz)Step (kHz)Depth of defect (mm) (mm) (mm)
Surface defectsSubsurface defects

10~1000101, 2, 3, and 41, 2, 3, and 431.5