Research Article

A Comprehensive Study on Gamma Rays and Fast Neutron Sensing Properties of GAGOC and CMO Scintillators for Shielding Radiation Applications

Table 3

Theoretically and experimentally obtained values of mass attenuation coefficients and effective atomic numbers of the GAGOC and CMO scintillator materials.
(a)

Energy (keV)Mass attenuation coefficients (μm) (cm2/g)
GAGOCCMO
This workExp. [1]This workExp. [1]

287.300.1790.18960.12710.1264
340.800.1420.15410.11160.1108
399.000.1180.12590.10060.1032
481.600.0990.10340.09000.0902
562.700.0870.09000.08260.0843
662.000.0770.08000.07580.076

(b)

Energy (keV)Effective atomic numbers (Zeff) (e/atom)
GAGOCCMO
This workExp. [1]This workExp. [1]

287.3032.5638.617.7918.12
340.8029.9535.417.1517.32
399.0028.0731.9116.7417.39
481.6026.3929.1516.4016.59
562.7025.3727.5616.2116.66
662.0024.5926.6416.0716.21