Research Article

Statistically Coherent Calibration of X-Ray Fluorescence Spectrometry for Major Elements in Rocks and Minerals

Table 2

Regression (x-y): matrix-corrected intensity-concentration (IntCorr-Conc) parameters.

ElementRegressionNumber of data pairs (calibrators)Regression equation parametersQuality of regression equation
Variables -ModelIntercept ()Slope ()

SiO2IntCorr-ConcOLR6010.85411.67624.46410.14520.00550.01460.961050.92362
IntCorr-ConcUWLR60−0.01480.97652.60060.18480.00320.00850.991570.98321

TiO2IntCorr-ConcOLR600.03440.02200.05870.07360.00160.00430.986440.97307
IntCorr-ConcUWLR600.00200.02040.05420.08010.00150.00400.991140.98235

Al2O3IntCorr-ConcOLR60−0.16750.67631.80110.15140.00560.01500.962370.92615
IntCorr-ConcUWLR60−0.00700.44191.17690.13970.00370.00980.985570.97135

Fe2O3tIntCorr-ConcOLR60−2.05760.59601.58730.21600.00660.01750.974190.94904
IntCorr-ConcUWLR60−0.00920.54581.45360.17720.00600.01600.981120.96259

MnOIntCorr-ConcOLR60−0.04120.00670.01780.02140.00030.00090.993480.98700
IntCorr-ConcUWLR600.00010.01340.03560.01650.00070.00170.991600.98328

MgOIntCorr-ConcOLR60−0.09770.27480.73190.26180.00640.01700.983170.96662
IntCorr-ConcUWLR60−0.00140.26920.71680.23760.00630.01670.987450.97505

CaOIntCorr-ConcOLR601.05610.21730.57890.06310.00140.00370.986430.97304
IntCorr-ConcUWLR600.00640.46161.22930.08530.00290.00780.986570.97331

Na2OIntCorr-ConcOLR600.04470.05670.15110.36240.00770.02050.987160.97449
IntCorr-ConcUWLR600.00540.04210.11220.35580.00570.01520.993450.98693

K2OIntCorr-ConcOLR60−0.07200.04300.11460.07190.00070.00200.996910.99383
IntCorr-ConcUWLR600.00820.03910.10420.06870.00070.00180.997930.99587

P2O5IntCorr-ConcOLR600.05370.01280.03410.02410.00080.00210.969720.94035
IntCorr-ConcUWLR600.00100.02020.05380.03200.00130.00330.969290.93952

, intercept; , standard error; , uncertainty at 99%; , slope; , linear correlation coefficient; , squared linear correlation coefficient.