Research Article

Processing Window and Microstructure of NiCoCrAlY Coating Deposited on Cast Iron Using Multilayer Laser Cladding

Table 5

Size of the columnar dendrite region and its variation with the number of deposited layers.

Layer number123456

Total height of coating (mm)0.851.051.251.421.561.66
Thickness of columnar dendrite region (mm)0.340.470.610.800.971.06
RC (%)40.044.848.856.362.263.9