Abstract

Energy drinks have been studied due to their damaging side effects on the health of their consumers when consumed in excess or when combined with alcohol. Our objective was to develop chemometric models, based on Fourier-transform mid-infrared (FT-MIR) spectroscopy, to quantify the taurine and caffeine content in energy drinks rapidly and simultaneously. The taurine and caffeine content in the 50 samples ranged between 0 and 69.51 mg/100 mL and 14.92 and 1126.17 mg/100 mL, respectively. The best prediction model was obtained with the partial least squares (PLS1) algorithm; for taurine, the following values were obtained: determination coefficient of calibration (Rc2) = 0.9999, standard error of calibration (SEC) = 0.15, determination coefficient of validation (Rv2) = 0.9997, and standard error of prediction (SEP) = 0.16; for caffeine, Rc2 = 0.9999, SEC = 0.26, Rv2 = 0.9999, and SEP = 0.32. The model developed with PLS1 showed certainty in predictions during the validation stage and during application to external samples. FT-MIR coupled to chemometrics is a reliable and fast technique (compared to conventional techniques) to quantify taurine and caffeine in energy drinks simultaneously.

1. Introduction

Energy drinks usually contain carbohydrates, vitamins, minerals, and taurine and caffeine in higher amounts. There is no official international legislation that establishes the maximum allowed limit (MAL) for taurine in these drinks, although there is a recommendation of 40 mg of acceptable daily intake (ADI) [1, 2]. The Mexican regulation [3] indicates that the MAL for caffeine in energy drinks must be of 20 mg/100 mL; likewise, the same norm indicates that the ADI for caffeine cannot exceed 165 mg.

Excessive or inadequate consumption (for example, combined with alcohol) of energy drinks has become a public health concern. With the increase in their consumption, the ADI of the main ingredients (taurine and caffeine) found in the energy drinks could easily exceed and increase the noxious side effects in consumers, such as increase in blood pressure, hypoglycemia, dizziness, diarrhea, peptic ulcer, arrhythmias, dehydration, and cerebral and nervous system damage [4].

In some energy drinks, the labels of the product do not provide detailed information on the ingredients or do not indicate the amount at which the main ingredients (taurine and caffeine) are contained. Therefore, the need arises to count upon analysis methods that will allow verifying and controlling the taurine and caffeine concentrations in energy drinks. Many analytical methods have been developed to quantify taurine and caffeine contents in energy drinks. To quantify taurine, micellar electrokinetic chromatography (MEKC) [5], capillary electrophoresis, UV-Vis spectroscopy [6], nuclear magnetic resonance (NMR) [7], and high-performance liquid chromatography (HPLC) with different detectors [8, 9] have been used. To quantify caffeine, different techniques have been used: HPLC [10], gas chromatography (GC), thin layer chromatography, UV-Vis spectroscopy, and NMR [5].

The mentioned techniques have been efficacious to determine taurine and caffeine in energy drinks; however, all these techniques require a complex pretreatment before the analysis, are time-consuming and laborious, and use large amounts of reagents and solvents (noxious for the analyst and the environment). Fourier-transform mid-infrared (FT-MIR) spectroscopy is a very useful technique to determine chemical components in foods, as it is fast, samples need minimal or nil pretreatment, and it does not produce toxic wastes. Although UV-Vis spectroscopy also has the aforementioned advantages, this technique is considered univariate, unlike FT-MIR spectroscopy, which is multivariate when coupled to chemometrics. Therefore, FT-MIR spectroscopy is an alternative to conventional methods because, coupled to multivariate analysis, it allows developing prediction models that will enable to know quantitatively the composition of the sample without performing pretreatments and without the use of solvents and reagents [11]. FT-MIR spectroscopy has been used to quantify taurine in energy drinks [12]; however, it has not been used to quantify caffeine in this type of drinks; in addition, FT-MIR spectroscopy together with multivariate analysis has not been used to quantify taurine and caffeine simultaneously. Therefore, this study represents, to the best of our knowledge, the first study aimed at solving this issue.

The objective of this work was to develop chemometric models based on FT-MIR spectroscopy to quantify taurine and caffeine simultaneously in energy drinks aiming to develop a simple, fast, and reliable methodology.

2. Materials and Methods

2.1. Samples

Fifty samples of energy drinks of different brands were selected randomly and acquired from different supermarkets and convenience stores in Mexico City, Mexico. All samples were stored at room temperature (±20°C) until their analyses.

2.2. Determination of Taurine

Taurine was quantified in triplicate by the technique described by Lau et al. [13]. The calibration curve was prepared with a stock solution of 400 mg/L of taurine (Sigma Chemical, St. Louis, MO, USA), and this solution was used to obtain the calibration standards with concentrations of 6, 25, 50, 100, 200, and 400 mg/L. In each standard solution, the absorbance was determined at 630 nm (spectrophotometer Jenway, model 7305, Staffordshire, UK), with distilled water as the blank. To analyze the samples (previously degassed), a 2 mL aliquot was taken and placed in a precipitation flask together with 4 g of ionic exchange resin. The mixture was agitated for 15 min and filtered (Whatman 40). The filtrate was gauged to 10 mL with distilled water. Then, 2 mL of the filtrate was supplemented with 2 mL of phosphate buffer, 2 mL of phenol, and 2 mL of sodium hypochlorite and gauged to 10 mL with distilled water. Afterwards, the solution was mixed and left to rest for 30 min. The absorbance was read at 630 nm against a blank of the buffering phosphate, phenol, and sodium hypochlorite solution. Results were expressed in milligrams per 100 mL (mg/100 mL).

2.3. Determination of Caffeine

Caffeine was quantified in triplicate following the technique described by Jenway [14]. The calibration curve was constructed with a stock solution of 100 mg/L of caffeine (Sigma Chemical, St. Louis, MO), and this solution was used to obtain calibration standards with concentrations of 5, 10, 20, 30, 40, 50, and 80 mg/L. The absorbance was determined in each standard solution at 260 nm (Jenway spectrophotometer, model 7305, Staffordshire, UK) with distilled water as the blank. 50 mL of the degassed sample was supplemented with 25 mL chloroform in a separation funnel. The funnel was inverted three times, ventilating it after each inversion. Afterwards, the chloroform layer was removed, and the extraction procedure was repeated twice. Finally, the absorbance was read at 260 nm against a chloroform blank. Results were expressed in milligrams per 100 mL (mg/100 mL).

2.4. Statistical Analysis

All results were analyzed through one-way ANOVA and Tukey’s multiple comparisons of means (). Statistical analyses were performed with Minitab version 16.1.0 software (State College, PA, USA).

2.5. FT-MIR Spectra

FT-MIR spectra were recorded in a Fourier-transform infrared spectrophotometer (FTIR) (model GX, PerkinElmer®, Massachusetts, USA), with attenuated total reflectance (ATR) and zinc selenide crystal (ZnSe) (model 022-12xx, PerkinElmer®, Massachusetts, USA). To obtain the data, Spectrum version 5.3.1 software was used (PerkinElmer®, Massachusetts, USA).

FT-MIR spectra were obtained in the mid-infrared region (4000–550 cm−1) with 64 scans at a resolution of 4 cm−1, in absorbance units (A). Before obtaining the FT-MIR spectra of the samples, the reference spectrum against air was determined to eliminate the spectral contribution of the environment. This was achieved by reading the empty ATR crystal under the same instrumental conditions of the sample, and the result was taken as the reference blank. The FT-MIR spectra were obtained with 1 mL of each sample (previously degassed) on the ZnSe crystal. Readings of samples were performed in triplicate, and then they were averaged with Spectrum version 5.3.1 software (PerkinElmer®, Massachusetts, USA). After ending each determination, the ZnSe crystal was carefully washed with a liquid detergent, rinsed with distilled water, cleaned with disposable wipes, and left to dry in the environment.

2.6. Multivariate Analysis

The multivariate analysis was performed with Spectrum Quant+ version 4.51.02 software (PerkinElmer®, Massachusetts, USA), which includes the principal component regression (PCR) algorithm and the partial least squares (PLS1 and PLS2). The regression model was built with 50 average FT-MIR spectra. Forty average FT-MIR spectra were used to calibrate the model and 10 average FT-MIR spectra to validate the model.

The spectra pretreatments to improve the predictive ability of the model included smoothing using the Savitzky–Golay algorithm with 19 points to eliminate the random noise present in the signal and to increase the signal/noise relation, the baseline correction (offset) to correct changes in the baseline deviation, second derivative with 13 points to increase spectral differences, and normalization using multiplicative correction of scattered light (MSC) to reduce multicolinearity and the effects of the baseline shift and curvature on spectra arising from scattering effects due to physical effects.

The model with the best calibration was selected based on (1) factors or latent variables, (2) coefficient of determination of calibration (Rc2), and (3) standard error of calibration (SEC) [15].

The predictive ability of the model was evaluated with (1) coefficient of validation (Rv2), (2) standard error of prediction (SEP), (3) Mahalanobis distance (MD), (4) residual ratio (RR), (5) residual error (RE), (6) ratio of performance to deviation (RPD), and finally, (7) relative difference percentage (%RD) which was calculated with the following equation:

2.7. Application of the Model

The model was applied to five energy drinks different from those used in the calibration and validation stages. Application of the model is relevant to evaluate the prediction of unknown samples, and this stage is used as another evidence to verify the predictive ability of the model.

3. Results and Discussion

3.1. Taurine Concentration

The taurine content of energy drinks varied from 0 to 69.51 mg/100 mL (Table 1). ANOVA analysis revealed a significant difference among samples (). The taurine content reported in the label of the product is very similar to that found in this work. However, 62% of energy drinks had no label information on their taurine content. In 10% of samples (drinks 1, 13, 24, 26, and 36), no taurine was detected. The literature reports the taurine concentration in energy drinks from nondetected (ND) to 315.3 mg/100 mL [5, 79]. The taurine content found in this work agreed with that reported in the literature.

It is recommended worldwide that the ADI for taurine should be 40 mg [1, 2]. Of the analyzed energy drinks, 99% (49 energy drinks) were below the ADI for taurine. Energy drink No. 2 exceeded the recommendation as it contained 69.51 mg/100 mL of taurine. There is no official international legislation that establishes the MAL for taurine in energy drinks. Because of this, the manufacturer is not bound to include information on the amount of this amino acid in its product. However, it is essential to know the impact of the ingredients of energy drinks and, according to the risks, to implement regulating measurements to avoid negative consequences to the consumer.

3.2. Caffeine Concentration

The caffeine content in energy drinks varied significantly (), from 14.92 to 1126.17 mg/100 mL (Table 1). Of the analyzed energy drinks, 94% (47 samples) exceeded the MAL for caffeine established in NOM-218-SSA1-2011, and only 6% (3 samples) (drinks 18, 26, and 32) complied with NOM-218-SSA1-2011 [3].

Energy drink No. 30 presented the highest caffeine concentration (1126.17 mg/100 mL). The reason for this high concentration is that among its ingredients, aside from caffeine, are guarana extracts, and this fruit is rich in caffeine, as it has 4 times more caffeine than coffee beans, aside from having other methylxanthines such as theobromine and theophylline [16].

The caffeine content reported on the product’s label is different from that quantified in this research; for example, the label of energy drink No. 8 reports a caffeine concentration of 19.5 mg/100 mL, and the chemical analysis quantified 27.42 mg/100 mL. In addition, on some labels, the caffeine content was not reported.

The literature reports caffeine concentrations in energy drinks from nondetected to 2500 mg/100 mL [5, 10]. The caffeine content obtained in this work varies with respect to other studies; this could be due to the lack of legislation. For example, the European Union (EU) has not established the MAL of caffeine in energy drinks; it has only indicated that if the product contains more than 150 mg/L of caffeine, the product must be labelled as “high caffeine content,” and this legend must be placed together with the name of the product. Likewise, the EU establishes that the label of the product must clearly indicate the caffeine content per 100 mL [17]; however, energy drinks that do not comply with this regulation are marketed freely.

Results indicate that the main energizing ingredient of these drinks is caffeine, as this compound was quantified in all drinks, whereas taurine was only quantified in some of them, for example, in drink No. 26, no taurine was quantified; however, it presents “high caffeine content” (656.8 mg/100 mL).

It is important to control the amount of energizing ingredients (taurine and caffeine) in energy drinks because their consumption has increased in the population with the promise of keeping them alert and active for longer time spans. The World Health Organization (WHO) has pointed out that the increase in the consumption of energy drinks is a public health concern, in particular, in youngsters who commonly mix them with alcohol. There are studies indicating that energy drinks are combined with alcohol [18], which increases the intoxication level in the consumer. Studies in humans suggest that the greatest desire to drink alcohol occurs when it is mixed with energy drinks, which increases the possibility of developing alcohol dependency [19].

3.3. FT-MIR Spectra

The chemical composition of energy drinks can be related to their FT-MIR spectra because the ingredients of energy drinks have characteristic functional groups that absorb in the FT-MIR spectrum and produce vibrational signals associated mainly with these constituents (Figure 1). The band at 3570–3200 cm−1 is due to stretching vibrations of the O-H bond found in molecules such as water. The peak at 2970 cm−1 is related with the stretching vibrational movements of functional group CH3, and the peak at 2935 cm−1 is due to the stretching vibrations of group CH2 [11].

In the region of the fingerprint (1800–900 cm−1), the absorption of the functional groups of taurine and caffeine is observed. At 1650–1550 cm−1, the stretching vibrations of functional group N-H of taurine are presented [12]. The most intense bands for caffeine are presented at 1300 cm−1, and they are due to the bending movements of the C-N bond. The small bands at 1241 cm−1 have been assigned to stretching vibrations of the C-C bond of caffeine [20]. Finally, bands at 1100–1000 cm−1 are due to the strong absorption characteristic of the SO2 compound of taurine [12].

3.4. Multivariate Analysis

Models were built in the 1600–950 cm−1 spectral region since this region had the highest correlation of the absorbance of each wavelength number with taurine and caffeine concentrations. The results of the chemometric models are depicted in Table 2. The R2 value indicates the correlation of the specified value against the estimated one by the chemometric model. Values of R2 higher than 0.9 suggest excellent quantitative information; in contrast, values between 0.81 and 0.66 indicate poorly reliable quantitative predictions [21]. Values of SEC and SEP are the same as the reference value and indicate the regression error; consequently, low values are desirable.

Based on the above, the model with the best adjustment was that developed with PLS1 by obtaining, for the two parameters (taurine and caffeine), Rc2 values close to 1 (0.9999) and lower SEC values (taurine: 0.15 and caffeine: 0.26) and SEP values (taurine: 0.16 and caffeine: 0.32) as compared to the models developed with the other algorithms. Likewise, the Rv2 values were very close to 1 (Rv2: 0.9997 and 0.9999) for both parameters (Figure 2). Also, latent variables (factors) were 5 and 7 for taurine and caffeine, respectively. Factors represent a significant source of data variations in FT-MIR spectra. Thus, the optimal number of factors is that which provides the lowest SEP.

The validation values that helped define the certainty of the predictions are depicted in Table 2. The Mahalanobis distance (MD) value was lower than 1 (taurine: 0.11–0.54 and caffeine: 0.13–0.45), which indicates that there was similitude between the FT-MIR spectra of the validation samples and the spectra of the calibration set. The Mahalanobis distance is a reliability parameter for the predicted result. The problem samples that are not representative can be identified through the Mahalanobis distance. A distance greater than 1 indicates that the spectral characteristics of the unknown sample are not reflected in the group of standards used in the calibration model. The residual ratio (RR) value was below 3 (taurine: 0.64–1.78 and caffeine: 0.87–1.91), suggesting that the validated spectrum has characteristics modeled by the number of selected factors. The residual error (RE) value was low (taurine: 0.74–0.95 and caffeine: 0.63–0.81), which is a measure of the error associated with the calculated property value and represents 95% confidence limits (two standard deviations). The RE is reported in the same units as the property value. The ratio of performance to deviation (RPD) values ranged from 8.67 to 14.37; according to Williams [22], the RPD values between 3.1 and 4.98 are considered acceptable, between 5 and 6.39 are good, and between 6.4 and 8 are very good for analytical purposes. The RPD is a measure of the goodness of fit, and it is defined as the ratio between the standard deviation (SD) of the reference data and the SEP. High values of the RPD are desirable; the higher the RPD, the more accurate the data fitted by the calibration. Finally, the relative difference percentage (%RD) for all validation samples was lower than 9%; according to Granato and Ares [23], percentages of RD ≤ 10% are considered excellent. These results indicated that the model developed with PLS1 performed an excellent prediction.

After validating the model, it was applied to five energy drinks different from the calibration and validation set. Results (Figure 3) confirmed the accuracy of the model developed with PLS1 since its values were very similar to those obtained with the UV-Vis spectrophotometric method (R2 ≥ 0.9); therefore, the values predicted by the model can be considered acceptable.

4. Conclusions

The chemometric model developed with PLS1 predicts the taurine and caffeine content of energy drinks simultaneously with certainty. FT-MIR spectroscopy coupled to multivariate analysis yielded similar values to those obtained with conventional analyses, but more economical and faster (measurements can be achieved in 5 min), without using solvents or pretreatment of samples, as compared to conventional methods that are time-consuming and require considerable amounts of reagents and solvents, considered environmentally damaging. The present method is fast and reliable and may be suitable for routine analysis of energy drinks. The results obtained in this study show that the legislation is necessary to regulate and control the content of taurine and caffeine in energy drinks to avoid adverse health effects. This is because many energy drinks do not provide detailed information on the ingredients or do not indicate the amount in which the main ingredients (taurine and caffeine) are contained. Furthermore, studies must be carried out to develop chemometric models to predict the chemical composition of energy drinks.

Data Availability

The data used to support the findings of this study are available from the corresponding author upon request.

Conflicts of Interest

The authors declare that there are no conflicts of interest related to this manuscript.

Acknowledgments

The authors wish to thank Escuela Nacional de Ciencias Biológicas-Instituto Politécnico Nacional (ENCB-IPN) for the financial support. M.G.-V. wishes to express her gratitude to Consejo Nacional de Ciencia y Tecnología (CONACYT) for the scholarship provided.