Research Article

Cerium Bromide Single-Crystal X-Ray Detection and Spectral Compatibility Assessment with Various Optical Sensors

Table 1

CeBr3 spectral matching with various available sensors.

Optical sensorsCeBr3Optical sensorsCeBr3

CCD broadband AR coating0.76GaAsP phosphor photocathode0.35
CCD infrared (IR) antireflection (AR) coating0.42Extended photocathode (E-S20)0.95
CMOS hybrid blue antireflection (AR) coating0.51Si PM MicroFC-30035-SMT0.86
Hybrid CMOS blue0.63Si PM MicroFB-30035-SMT0.78
CMOS (monolithic 0.25 μm)0.32Si PM MicroFM-100350.34
a-Si:H passivated0.55Si PM S10985-050C0.86
a-Si:H nonpassivated0.84Si PM S10362-11-025U0.86
CCD indium tin oxide (ITO) gates, microlenses0.58Si PM S10362-11-050U0.82
CCD with indium tin oxide (ITO) gates0.39Si PM S10362-11-100U0.88
CCD with polygates0.03Flat panel PS-PMT H8500C-030.99
CCD no polygate LoD0.19Flat panel PS-PMT H8500D-030.95
CCD with traditional polygates0.20Flat panel PS-PMT H10966A0.96
CMOS (photogate array 0.5)0.14Flat panel PS-PMT H8500C0.97
CMOS RadEye HR0.05Bialkali photocathode0.95
GaAs photocathode0.94Multialkali photocathode0.97