Research Article
Self-Organizing Wearable Device Platform for Assisting and Reminding Humans in Real Time
Table 3
Performance evaluation for fault activity identification and alarm activation.
| Activity | Fault or alerting condition | Response time after fault condition (ms) | Success ratio (%) |
| Gas oven | Door-lock (outside) open | 565 | 97.69 | Predefined timeout | 610 | 99.03 | Faucet | Door-lock (outside) open | 512 | 96.78 | Predefined timeout | 550 | 98.58 | Coffee port | Door-lock (outside) open | 570 | 98.23 | Number of cups per day (predefined) exceeded | 780 | 92.31 | Scheduled pill time | Pill time approaching/exceeded | 220/620 | 99.27/98.72 | Scheduled blood-sugar measurement | Measurement time approaching/exceeded | 210/610 | 99.98/99.42 | Toilet | Exited the bathroom without flushing | 1600 | 89.67 | Timeout (predefined) after toilet usage (stay in bathroom overly long) | 750 | 92.39 |
|
|