Research Article

Self-Organizing Wearable Device Platform for Assisting and Reminding Humans in Real Time

Table 3

Performance evaluation for fault activity identification and alarm activation.

ActivityFault or alerting conditionResponse time after fault condition (ms)Success ratio (%)

Gas ovenDoor-lock (outside) open56597.69
Predefined timeout61099.03
FaucetDoor-lock (outside) open51296.78
Predefined timeout55098.58
Coffee portDoor-lock (outside) open57098.23
Number of cups per day (predefined) exceeded78092.31
Scheduled pill timePill time approaching/exceeded220/62099.27/98.72
Scheduled blood-sugar measurementMeasurement time approaching/exceeded210/61099.98/99.42
ToiletExited the bathroom without flushing160089.67
Timeout (predefined) after toilet usage (stay in bathroom overly long)75092.39