Step Estimator Based on a Wearable ECG Monitor

Table 1

Gait detection results in treadmill test for participant 1 along with the average accuracy from all five participants using IMF 6 and IMF 7 with various belts tightness.

Treadmill speed (km/h)Accuracy of 85% of CCAccuracy of 90% of CCAccuracy of 95% of CCAccuracy of 100% of CC
IMF 6 (%)IMF 7 (%)IMF 6 (%)IMF 7 (%)IMF 6 (%)IMF 7 (%)IMF 6 (%)IMF 7 (%)
ABABABABABABABAB

1.840.00−3.4692.6385.522.04−15.3997.9693.52−14.00−3.0278.0087.12−6.32−13.8596.8493.67
2.723.301.5091.2694.103.77−1.3592.4596.59−7.6911.0988.4692.3319.2310.4394.2392.13
3.654.5513.1885.4594.570.004.7899.0895.73−3.7022.4198.1589.5058.9318.6271.4386.07
4.566.6721.2968.3891.888.6230.27100.0088.786.8428.8190.6086.0088.3340.3665.0081.81
5.439.7344.6073.9779.1030.9961.7195.7775.4735.6257.0778.0868.1798.6883.3959.2160.06
6.332.8847.7779.4579.3226.0362.7797.2677.7354.7956.5276.7168.7698.6888.0061.8458.62
7.219.8741.3292.7279.3222.5254.8999.3475.2675.6867.2478.3866.7398.7293.7258.9754.17
8.120.5142.4889.7475.5752.2962.6091.5071.4864.9075.3876.8259.8083.5495.0549.3750.79
9.048.1052.7581.0171.8058.2375.3275.9561.0687.1891.9067.9553.6885.8996.1551.5352.03
Avg.38.4029.0583.8583.4622.7237.2994.3781.7433.2945.2781.4674.6869.5256.8767.6069.93

A, participant 1; B, average.