Research Article

Seismic Performance of New Fabricated Lightweight Herringbone Support Seismic Wall Based on ZigBee Sensor Technology

Table 2

Interstory displacement and interstory displacement angle without supporting structure under earthquake action.

FloorTwo-way earthquake action
Floor lateral displacement (mm)Displacement angle between floors (rad)Floor longitudinal displacement (mm)Displacement angle between floors (rad)

12.79821/9982.19861/1339
25.97891/8975.38951/938
39.49761/8918.59681/929
412.70151/96110.98731/1139
514.97631/120113.46071/1372