Research Article

Seismic Performance of New Fabricated Lightweight Herringbone Support Seismic Wall Based on ZigBee Sensor Technology

Table 4

Interstory displacement and interstory displacement angle of a herringbone support structure under earthquake action.

FloorTwo-way earthquake action
Floor lateral displacement (mm)Displacement angle between floors (rad)Floor longitudinal displacement (mm)Displacement angle between floors (rad)

11.98591/15011.59891/1839
24.70011/10894.00231/1328
37.80311/9715.97891/1301
49.89781/14027.09821/1604
512.0051/14979.80281/1862