Research Article
Solving Unit Commitment Problem Using Modified Subgradient Method Combined with Simulated Annealing Algorithm
Table 3
Unit characteristics for ten-unit thermal plant.
| Unit | | | SC | SC | a | b | C | | | No | (MW) | (MW) | (hot)($) | (cold)($) | ($/h) | ($/MWh) | ($/MW2h) | (MW/h) | (MW/h) |
| 1 | 150 | 455 | 4500 | 9000 | 1000 | 16.19 | 0.00048 | 130 | 130 | 2 | 150 | 455 | 5000 | 10000 | 970 | 17.26 | 0.00031 | 130 | 130 | 3 | 20 | 130 | 550 | 1100 | 700 | 16.60 | 0.00200 | 60 | 60 | 4 | 20 | 130 | 560 | 1120 | 680 | 16.50 | 0.00211 | 60 | 60 | 5 | 25 | 162 | 900 | 1800 | 450 | 19.70 | 0.00398 | 90 | 90 | 6 | 20 | 80 | 170 | 340 | 370 | 22.26 | 0.00712 | 40 | 40 | 7 | 25 | 85 | 260 | 520 | 480 | 27.74 | 0.0079 | 40 | 40 | 8 | 10 | 55 | 30 | 60 | 660 | 25.92 | 0.00413 | 40 | 40 | 9 | 10 | 55 | 30 | 60 | 665 | 27.27 | 0.00222 | 40 | 40 | 10 | 10 | 55 | 30 | 60 | 670 | 27.79 | 0.00173 | 40 | 40 |
|
|