Research Article
Stochastic Dynamic Programming Applied to Hydrothermal Power Systems Operation Planning Based on the Convex Hull Algorithm
Table 5
Stage 2 expected costs.
|
Water storage (%) | 100 | 50 | 0 |
|
Water inflow (hm3) | 17 | 13 | 17 | 13 | 17 | 13 |
| Optimal decision | | 67 | 67 | 39.2 | 39.2 | 0 | 0 | | 50 | 50 | 27.8 | 27.8 | 17 | 13 | | 0 | 0 | 20 | 20 | 20 | 20 | | 0 | 0 | 0 | 0 | 9.7 | 13.3 | Uns | 0 | 0 | 0 | 0 | 0 | 0 |
|
Immediate cost ($) | 0.0 | 0.0 | 200.0 | 200.0 | 394.0 | 466.0 |
|
Future cost ($) | 0.0 | 0.0 | 104.3 | 143.0 | 484.0 | 484.0 |
|
Mean optimal cost ($) | 0.0 | 323.6 | 914.0 |
|
|