Research Article
Seismic Response of Power Transmission Tower-Line System Subjected to Spatially Varying Ground Motions
Table 5
Maximum response of cable under various angle excitations.
| Number | Degree | Cable 1 (N) | Cable 2 (N) | Cable 3 (N) | Cable 4 (N) |
| I | | 5238 | 9646 | 9613 | 9849 | II | | 5162 | 9642 | 9579 | 9861 | III | | 5830 | 10416 | 9915 | 9816 | IV | | 5644 | 10667 | 9603 | 10105 | V | | 5219 | 9665 | 9326 | 10218 |
|
|