Research Article

Seismic Response of Power Transmission Tower-Line System Subjected to Spatially Varying Ground Motions

Table 8

Maximum response of tower under different wave travel excitations.

Apparent velocityAxial force (N)Moment (N·m)Shear force (N)Displacement (cm)

Uniform237045623182.44
200 m/s905502969171612.3
400 m/s68679218512628.39
800 m/s345789295153.75
1600 m/s271736673812.46