Research Article

Fractal Dimension Analysis of Higher-Order Mode Shapes for Damage Identification of Beam Structures

Figure 13

Experimental crack identification from SLV-measured eleventh-order mode shape of cracked cantilever beam. (a) Normalized eleventh-order mode shape; (b) affine transformed mode shape; (c) KFD trajectory showing a singular peak attributed to the crack.
454568.fig.0013a
(a)
454568.fig.0013b
(b)
454568.fig.0013c
(c)