Research Article

Structural Damage Identification of Pipe Based on GA and SCE-UA Algorithm

Table 6

The degree damage table of Point D at inclined pipe DG in genetic algorithm.

Cell number1–151617–3300

Case
 Design value of damage degree 0.0000.1000.000
 Identification value of damage degree0.0000.0920.000
Case
 Design value of damage degree 0.0000.2000.000
 Identification value of damage degree0.0000.1890.000
Case
 Design value of damage degree 0.0000.3000.000
 Identification value of damage degree0.0000.2810.000
Case
 Design value of damage degree 0.0000.4000.000
 Identification value of damage degree0.0000.3870.000