Research Article

A Sustainability-Oriented Multiobjective Optimization Model for Siting and Sizing Distributed Generation Plants in Distribution Systems

Table 3

Cost and operation parameters of DG units.

ā€‰ ($/kW) ($/kWh) (yr) (h)CEC (GJ)AbatE (GJ) (GJ)

WT 1,8000.050.05252,100118.350.820,120.1
PV2,000 0.030.05301,650406.5189.218,970.4
MNGT850 0.040.05306,00033,348.79,701.2105,426.7