Research Article
Study on Optimal Placement and Reasonable Number of Viscoelastic Dampers by Improved Weight Coefficient Method
Table 7
Story drift of the structure with dampers for case 3 (mm).
| Story | El Centro | Northridge | Imperial Valley | Tianjin |
| 1 | 4.23 | 6.12 | 4.14 | 10.00 | 2 | 5.01 | 7.58 | 5.13 | 14.59 | 3 | 5.91 | 7.00 | 4.82 | 14.16 | 4 | 6.21 | 8.51 | 7.64 | 13.51 | 5 | 6.72 | 10.11 | 12.71 | 12.51 | 6 | 9.94 | 13.58 | 14.80 | 13.27 | 7 | 11.07 | 12.70 | 13.08 | 17.22 | 8 | 13.48 | 11.13 | 10.09 | 17.69 | 9 | 12.72 | 9.25 | 6.09 | 16.59 | 10 | 10.74 | 7.30 | 6.44 | 14.59 | 11 | 8.37 | 5.75 | 6.42 | 12.87 | 12 | 6.43 | 4.71 | 5.77 | 10.40 | 13 | 4.72 | 3.48 | 5.25 | 7.86 | 14 | 3.91 | 2.47 | 4.50 | 5.29 | 15 | 2.43 | 1.71 | 2.81 | 2.83 |
|
|