Research Article
A Static Control Algorithm for Adaptive Beam String Structures Based on Minimal Displacement
Table 2
Static state results under load Case 1 with
= 5.2 kN/m.
| | Working status factors | Compressive stress values of struts (N/mm2) |
Adjustment values of struts (mm) |
Minimal and maximum tension values of cables (kN) | Maximum stress values of the beam (N/mm2) |
| Notations | | | | | | | | | | | Noncontrol results | 0.992↑ | −51.23 | −50.76 | −51.23 | 0.00 | 0.00 | 0.00 | 503.60 | 535.10 | 77.15 | LDC results | 0.085 | −59.18 | −39.71 | −59.18 | 261.60 | −47.70 | 261.70 | 506.77 | 540.58 | 87.16 | NDC results | 0.035 | −59.31 | −39.52 | −59.31 | 253.80 | −66.00 | 253.50 | 506.84 | 540.63 | 85.90 |
|
|